<Function 080> GS ( k pL pH cn fn m d1...dk (fn=80)
Code:
ASCII
GS ( k pL pH cn fn m d1...dk
Hex
1D 28 6B pL pH 30 50 30 d1...dk
Decimal
29 40 107 pL pH 48 80 48 d1...dk
Range:
4 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 255)
cn=48
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) – 3
Default:
None
Description:
This command stores the PDF417 symbol data (d1...dk) in the symbol storage area.
Remarks:
■ The data stored in the symbol storage area by this command remains reserved after processing Function 081 or 082.
■ The following data should not be included in the symbol data d1..dk since this information is automatically added by
the printer:
• Start pattern and stop pattern.
• Indicator codeword of left and right.
• The descriptor of symbol length (the first code word in the data area).
• The error correction codeword calculated by modulus 929.
■ The setting of this command remains effective until the following processing is performed:
• Executing Function 080
• Executing ESC @
• Executing printer reset or power-off
Differences:
None