<Function 169> GS ( k pL pH cn fn n (fn=69)
Code:
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 31 45 n
Decimal
29 40 107 3 0 49 69 n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=69
48n51
Default:
n = 48
Description:
This command sets the error correction level for QR Code.
n Function Recovery Amount (%)
48 Error Correction Level L 7
49 Error Correction Level M 15
50 Error Correction Level Q 25
51 Error Correction Level H 30
Remarks:
The setting of this command affects the processing of <Function 181> and <Function 182>.
Reed-Solomon correction is employed to generate a series of error correction codewords.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.