
SRP-F310/312
Rev. 1.00 BIXOLON
- 93 -
<Function 069> GS ( k pL pH cn fn m n (fn=69)
Code:
ASCII
GS ( k pL pH cn fn m n
Hex
1D 28 6B 04 00 30 45 m n
Decimal
29 40 107 4 0 48 69 m n
Range:
(pL + pH x 256) = 4 (pL=4, pH=0)
cn=48
fn=69
m=48
48 ≤ n ≤ 56
Default:
None
Description:
■ This command specifies the error correction level for PDF417.
• The error correction level is set by “level”.
Remarks:
■ Settings of this function affect the processing of Functions 081 and 082.
■ Error correction level specified by “level” (m=48) is as follows:
The number of the error correction codeword is unchanged regardless of the number of codeword in the data area.
n Function Number of error correction codeword
48 Error correction level 0 2
49 Error correction level 1 4
50 Error correction level 2 8
51 Error correction level 3 16
52 Error correction level 4 32
53 Error correction level 5 64
54 Error correction level 6 128
55 Error correction level 7 256
56 Error correction level 8 512
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None
Kommentare zu diesen Handbüchern