BIXOLON SRP-F312 Spezifikationen Seite 62

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 145
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 61
SRP-F310/312
Rev. 1.00 BIXOLON
- 62 -
<Function 1> GS ( E pL pH fn d1 d2 (fn=1)
Code:
ASCII
GS ( E pL pH fn d1 d2
Hex
1D 28 45 pL pH fn d1 d2
Decimal
29 40 69 pL pH fn d1 d2
Range:
(pL + pH x 256) = 1 (pL=1, pH=0)
fn=1
d1=73, d2=78
Default:
None
Description:
This command starts the user setting mode, enabling the printer to notify that the mode has changed as follows:
[Mode change feedback]
Hexadecimal Decimal Number of Data
Header 37H 55 1 byte
Flag 20H 32 1 byte
NUL 00H 0 1 byte
Remarks:
This command is effective only in standard mode, not in page mode.
Upon entering the user mode setting mode by this command, the printer transmits “mode change feedback” to the
host.
The user setting mode should be enabled prior to processing <Function 2> through 12. Otherwise, those functions
are ignored.
After confirming “mode change feedback”, it is recommended to send the command to reconfigure the NV user
memory.
Differences:
None
Seitenansicht 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 144 145

Kommentare zu diesen Handbüchern

Keine Kommentare