BS DC1 % (fn = 3)
Function: Select reverse printing function
Code:
ASCII
BS DC1 % fn n
Hex
08 11 25 03 n
Decimal
08 17 37 03 n
Range:
0 n 2
Default:
n = 0
Description:
When the printer receives Reverse Printing Start command (n = 1), the data will be stored in receive buffer until it
receives Reverse Printing End command (n = 2).
When the printer receives Reverse Printing End (n = 2), the data will be printed upside down compared to standard
mode.
After printing data, the printers will return to standard mode automatically.
Select reverse printing mode using the function number of n.
n Function
1
Starts reverse printing mode
2
Ends the reverse mode and prints the data in reverse.
Remarks:
None
Differences: