- 34 -
ESC J
Function: Print and feed paper
Code:
ASCII
ESC J n
Hex
1B 4A n
Decimal
27 74 n
Range:
0 n 255
Default:
None
Description:
This command prints the data in the print buffer and feeds the paper [n X vertical motion unit].
Remarks:
The maximum feed amount available varies depending on the printer model.
With standard mode selected, the vertical motion unit is used.
In page mode, the horizontal motion unit is applied when printing start poison is defined to the upper right or lower
right of print area using ESC T, otherwise, the vertical motion unit is used.
When used in page mode, this command moves only the print position, not executing actual printing.
Differences:
Vertical motion unit and maximum feed amount:
Model Vertical unit Max feed amount
SRP-F310 0.0705mm (1/360 inch) 17.98mm
SRP-F312 0.0625mm (1/406 inches) 15.937mm