SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 54 -
<Function 2> GS ( F pL pH m a nL nH (m=2)
Code:
ASCII
GS ( F pL pH m a nL nH
Hex
1D 28 46 04 00 02 a nL nH
Decimal
29 40 70 4 0 2 a nL nH
Range:
(pL + pH × 256) = 4 (pL = 4, pH = 0)
m = 2
a = 0, 48
0 (nL + nH × 256) 65535 (0 nL 255, 0 nH 255)
Default:
nL = 0, nH = 0
Description:
This command sets the value for the adjustment of paper cutting position after sensing BM.
pL, pH specifies (pL + pH × 256) as the number of bytes after pH (m, a, nL, and nH)
nL, nH specifies [(nL + nH × 256) × vertical motion units] as the adjustment value.
Remarks:
This command affects to the cutting operations as follows:
Paper cut by GS V m n.
Paper cut after paper feeding triggered by the paper FEED button.
Paper cut after initializing the BM.(optional)
Paper cut after paper feeding with the cover closed.(optional)
This command is only effective for the forward paper feeding.
The maximum adjustable length is 400 mm. If the adjustment value to be specified exceeds the maximum value, the
adjustment value is automatically set to the maximum value.
Differences:
None