GS ( A
Function: Execute test print
Code:
ASCII
GS ( A pL pH n m
Hex
1D 28 41 pL pH n m
Decimal
29 40 65 pL pH n m
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
0 ≤ n ≤ 2, 48 ≤ n ≤ 50
1 ≤ m ≤ 3, 49 ≤ m ≤ 51
Default:
None
Description:
■ This command prints a specified pattern for testing on a roll paper.
• Roll paper is selected with n specified as follows:
n Paper type
0, 48
1, 49
2, 50
Roll paper
• Different kinds of test patterns are selected according to m as follows:
m Test pattern
1, 49 Hexadecimal dump mode
2, 50 Printer configuration printing
3, 51 Rolling pattern printing
Remarks:
■ The printer cancels a macro definition in progress If this command is processed. The macro becomes invalid.
■ After completion of this command, a software reset is executed automatically to restore the printer status set during
power cycling.
■ All of the data transmitted from the host to the printer is printed and identified in hexadecimal dump mode.
■ The real time command and ASB operations are not executed during the printing of printer configuration (m=2, 50)
and rolling pattern (m=3, 51).