BIXOLON SPP-R300 Spezifikationen Seite 132

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 149
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 131
SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 132 -
GS r
Function: Transmit status
Code:
ASCII
GS r n
Hex
1D 72 n
Decimal
29 114 n
Range:
n=1, 2, 49, 50
Default:
None
Description:
The command transmits the status specified by n as follows:
n Function
1, 49 Transmits paper sensor status
2, 50 Transmits drawer kick-out connector status
Remarks:
The status is one byte.
The status to be transmitted is as follows:
Paper sensor status (n=1, 49):
Bit Off/On Hex Decimal Function
Off 00 0 Paper near-end sensor: Paper adequate
0, 1
On 03 3 Paper near-end sensor: Paper near end
Off 00 0 Paper end sensor: Paper present
2, 3
On 0C 12 Paper end sensor: Paper not present
4 Off 00 0 Fixed
5 Off 00 0 Reserved
6 Off 00 0 Reserved
7 Off 00 0 Fixed
Bits 2 and 3: This command can not be executed when the printer is offline due to the lack of paper. Therefore, the
status of bit 2 (1) and bit 3 (1) is not transmitted.