Rev. 1.03
- 42 -
SRP-350/352plusA&C
<Function 167> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 31 43 n
Decimal 29 40 107 3 0 49 67 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=67
1 ≤ n ≤ 8
n=3
Specifies the size of a module of QR Code symbol.
▪ Settings of this function affect the processing of Functions 181 and 182.
▪ The setting unit differs, depending on the printer models.
▪ Settings of this function are effective until ESC @ is executed, the printer
is reset, or the power is turned off.
▪ n = width of a module = height of a module. (Because the QR Code
modules are square.)
<Function 169> GS ( k pL pH cn fn n (fn=69)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 31 45 n
Decimal 29 40 107 3 0 49 69 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=69
48 ≤ n ≤ 51
n=48
Specifies the error correction level of QR Code.
n Function Recovery Capacity % (approx.)
48 Specify Error correction level L 7
49 Specify Error correction level M 15
50 Specify Error correction level Q 25
51 Specify Error correction level H 30
▪ Settings of this function affect the processing of Functions 181 and 182.
▪ QR Code employs Reed-Solomon error correction to generate a series of
error correction code words.
▪ Settings of this function are effective until ESC @ is executed, the printer
is reset, or the power is turned off.
<Function 180> GS ( k pL pH cn fn m d1...dk (fn=80)
[Format]
[Range]
[Description]
ASCII GS ( k pL pH cn fn m d1...dk
Hex 1D 28 6B pL pH 31 50 30 d1...dk
Decimal 29 40 107 pL pH 49 80 48 d1...dk
4 ≤ (pL + pH x 256) ≤ 7092 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 27)
cn=49
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) – 3
Stores the QR Code symbol data (d1...dk) in the symbol save area.