SRP-350/352plusII
Rev. 1.01 BIXOLON
<Function 067> GS ( k pL pH cn fn n (fn=67)
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
1 ≤ n ≤ 4
This command sets the width of the module of PDF417 symbol to n dots.
■ Settings of this command affect the processing of Functions 081 and 082.
■ The setting unit for printer models varies.
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
■ Setting unit(1 dot)
• SRP-350plusII: 0.141(1/180 inch)
• SRP-352plusII: 0.125(1/203 inch)