BIXOLON SPP-R200 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 65
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
Rev. 1.03
- 6 -
SPP-R200
3-3 Control Commands Details
HT
[Name]
[Format]
[Description]
Horizontal tab.
ASCII HT
Hex 09
Decimal 9
Moves the print position to the next horizontal tab position.
LF
[Name]
[Format]
[Description]
Print and line feed.
ASCII LF
Hex 0A
Decimal 10
In standard mode, prints the data in the print buffer and feeds one line
based on the current line spacing.
In page mode, modes the print position in memory to feed one line based
on the current line spacing.
FF
[Name]
[Format]
[Description]
If in page mode, after printing, the printer is returned to regular mode.
If the label function is set, the paper is fed up to the next printing position.
ASCII FF
Hex 0C
Decimal 12
All data collected to the current point is printed, and then the printer is
converted from page mode to regular mode.
If the label function is set, the paper is fed up to the next printing position.