
SPP-R210 Command Manual
Rev. 1.00 BIXOLON
<Function 112> GS ( F pL pH m aL aH bL bH (m=112)
(pL + pH × 256) = 5 (pL = 5, pH = 0)
m = 112
0 ≤ (aL + aH × 256) ≤ 65535 (0 ≤ aL ≤ 255, 0 ≤ aH ≤ 255)
0 ≤ (bL + bH × 256) ≤ 65535 (0 ≤ bL ≤ 255, 0 ≤ bH ≤ 255)
aL = 141, aH = 0 (BM height(top of a BM ~ bottom of BM): 20 mm)
bL = 20, bH = 11 (BM interval(top of a BM ~ top of next BM): 400 mm)
■ This command sets the black mark paper format.
• pL, pH specifies (pL + pH × 256) as the number of bytes after pH (m, aL, aH,bL, bH).
• aL, aH specifies [(aL + aH × 256) × vertical motion units] as the BM height.
• bL, bH specifies as [(bL + bH × 256) × vertical motion units] as the BM interval.
■ The available BM height ranges from 4 to 20 mm.
■ If the BM height specified is out of range, this command is ignored.
■ The BM interval ranges from 40 to 400 mm.
■ If the BM interval specified is out of range, this command is ignored.
Kommentare zu diesen Handbüchern